API DENSITY AND GRAVITY
CALCULATOR
Product Id: 11339API
GRAVITY CALCUALTOR l Corrects API Hydrometer Readings at any temperature (
F) to API degrees at 60 F. l Corrects Relative Density Hydrometer Readings
at any temperature ( F) to Relative Density at 60 l Converts API Gravity to
Relative Density* l Converts API Gravity to metric density Kg/cubic meter l
Converts API Gravity to weight in lbs per gallon 15 DENSITY CALCULATOR l
Converts density reading taken with a hydrometer to corrected density at 15
c l Separate Scales for 3 different types of fuel: KEROSENE WIDE CUT AVGAS
Jet A JP4 Jet A-1 Jet B JP 5 JP 8 l Scales read in KG/m *Relative
Density is now the accepted term for "specific gravity". INSTRUCTIONS for
API CALCULATOR - GTP-3012-1: 1. Rotate disk unitl the observed hydrometer
reading (API) is aligned with observed temperature, *F. 2. Read corrected
Degrees API at the 60 *F arrow. NOTE: If a relative density or specific
gravity hydrometer is used, set the hydrometer reading opposite the observed
temperature. Then read corrected relative density at the 60 F arrow.
|
|